korea.recycle.net
korea.recycle.net
korea.recycle.net
[ | NewsGroups | Main Menu | Add Listing | Price Reports ]

Other Used Equipment Newsgroup



EXPIRED LISTING - submitted on 2008-10-21.
Details and prices quoted are no longer current or valid.
Other Used Equipment : AVAILABLE TO SELL

Location: USA, LAKE MARY FLORIDA

Dranetz DranTech Xtra Pack Multimeters .
DranTech Xtra Pack 1 (DranTech Xtra, USB, DranWin10, ps, hard case, voltage leads, fuses, cal cert) These multimeters are suitable for universal use in electrical engineering, electrical installation, laboratory applications, telecommunication, technical training, as well as for troubleshooting in the field. Remote configured, and momentary and stored measurement data via the bidirectional infrared Interface with DranWin software Three Connector Terminals with patented Automatic Blocking Sockets* All current ranges are implemented via a single connector socket which prevents any possibility of operator error. Beyond this, the automatic blocking sockets prevent incorrect connection of the measurement cables, as well as selection of the wrong measured quantity. Danger to the user, the instrument and the device under test resulting from operator error is therefore eliminated. * Patented (patent no. DE 40 27 801 C2 and US 5,166,599) Overload Protection The instrument is safeguarded for up to 1000 V in all measuring functions by overload protection. Voltages of greater than 1000 V and current of greater than 10 or 16 A are indicated acoustically. RMS Value with Distorted Waveforms The measuring method applied allows for waveform independent RMS measurement (TRMS AC and AC+DC) for voltage and current up to 10 kHz). Selectable Filter for V AC Measurement A 1 kHz low-pass filter can be activated if required, for example when measuring motor voltage at electronic frequency converters. Battery Capacity Indication - Power Saving Circuit The battery load capacity is indicated on the display. If user selected, the device is switched off automatically if the measured value remains unchanged for a period of between 10 and 59 minutes (adjustable), and if none of the controls are activated during this time. DKD Calibration Certificate Multimeters are furnished with an internationally accepted DKD calibration certificate (recognized by EA and ILAC). After the specified calibration interval has elapsed (recommended interval: 1 to 3 years), the multimeters can be inexpensively recalibrated by any calibration laboratory. Scope of Delivery * Voltage 1000 V and current 10 A (Rms or DC) max measurements * Frequency, RMS value of AC measuring voltage * 4½-place display (11,999 counts), with display illumination * Automatic Blocking Sockets to prevent incorrect connection of the measurement cables * 1 khz low pass filter for V AC measurements * Square Wave signal measurement with amplitudes of 2 to 5 V and frequencies from 100 Hz to 1 Mhz * Capacitance measurement to 1000 uF * Resistance measurement to 40 Meg ohms * Temperature measurement in degrees Fahrenheit or Celsuis * Thermocouple measurement capabilibities of Type J and K thermocouples * Battery run time, approximately 200 hrs on 2 AA alkalines * Overload Protection, audible sound is employed if upper voltage or current range is exceeded * Fuse indicator displays message that the fuse for current measurements needs to be replaced * Bandwidth - 100 kHz * Frequency - 1 Mhz * Memory for data logging - 540 kb * Remote configured, and momentary and stored measurement data via the bidirectional infrared interface with DranWin software


Listing ID: LA845212
To view contact information to this listing,
ENTER YOUR EMAIL ADDRESS AND CLICK GO :


Quantity Units Frequency
1 each Daily
Price Funds Per Unit
825.00 USD each


NOTE : This is an archived listing and the details of the listing are outdated and no longer valid.
ID TYPE ITEMS ( Found : 1325 ) DATE
LW845669 Wanted VVTI Engine Toyota Camery 2005-2007. 2008-10-24 04:10:00
LA845500 Available USB guitar. 2008-10-23 04:06:00
LA845423 Available Tegam 2725A Function Generator . 2008-10-22 16:48:00
LA845422 Available Tegam 2730A Function Generator SPECIAL. 2008-10-22 16:44:00
LA845421 Available Tegam 2732A Function Generator . 2008-10-22 16:39:00
LA845212 Available Dranetz DranTech Xtra Pack Multimeters . 2008-10-21 15:09:00
LA845201 Available Wheel Loader. 2008-10-21 14:46:00
LA845197 Available Electric Power System. 2008-10-21 14:42:00
LA845020 Available Pedrazolli 14'' cold saw made in Italy. 2008-10-20 18:35:00
LW844849 Wanted used notebooks A-grade. 2008-10-19 13:34:00
LA844781 Available Whiting Systems Automated Truck Wash System. 2008-10-18 14:45:00
LA844510 Available osram 400w hps sont. 2008-10-17 00:25:00
LA844429 Available High security shredders. 2008-10-16 16:25:00
LA843410 Available 2004 Lefort Shear . 2008-10-10 14:30:00
LA843003 Available HD Pallet racking/Interlake style. 2008-10-08 12:14:00
LA842983 Available Raymond Turret Trk. 2008-10-08 11:05:00
LA842859 Available Commercial Trash Compactors. 2008-10-07 16:55:00
LA842801 Available Used office cubicles. 2008-10-07 11:41:00
LA842684 Available Used Projectors. 2008-10-06 22:40:00
LA842204 Available Stackable storage cages. 2008-10-03 14:16:00
LA841815 Available NPK Demolition Shear. 2008-10-01 14:04:00
LA841813 Available Mosley 330 Shear and Squeeze Box. 2008-10-01 14:00:00
LA841788 Available 1993 Liebherr A 912 Material Handler. 2008-10-01 12:42:00
LA841783 Available Al-jon 400 Car Crusher. 2008-10-01 12:16:00
LA841770 Available Lollini AL-5000 Car Baler. 2008-10-01 11:28:00
« Previous | More Items »
Submit an inquiry/message to the Forum
Other Used Equipment Newsgroup
Join this Forum
k o r e a . r e c y c l e . n e t
| Used Waste & Recycling Equipment | NewsGroups
Our Services | Email FeedBack | Privacy Policy | Main Menu

3 Drivers, Engenharia, Inovacao e Ambiente, S.A.             Industrial Energy Green Transition 2024 Conference


Cooksmill NetSystems Network File No:
Another Scrap.Net Venture